Product Information
Description
- cULus and cCSAus Certified
- 1-Year Limited Warranty
- Mechanism Only
- Free Shipping
Intermatic T104M201 24-Hour DPST Time Switch Mechanism with Pool Heater Protection
T100 Series mechanism with heater protection built in.
The Intermatic T104M201 is a 24-hour T100 Series mechanical time switch mechanism, double pole single throw (DPST), with pool heater protection. It runs on 208-277 VAC, 60 Hz, allows up to 12 ON/OFF operations per day and ships as the mechanism only, ready to install in most Intermatic enclosures.
Why PST Customers Pick This
Pool Heater Protection
Intermatic's heater control (fireman) switch instructions for this mechanism describe contacts that stay closed except for the 20 minutes before the pump is scheduled to turn off, so water circulates for 20 minutes without heat. The heater control output is rated 10 A, 250 VAC max.
Heavy Load Ratings
Intermatic rates the T104M201 at 40 A resistive (120-480 VAC), 40 A inductive (120-277 VAC) and motor loads of 2 HP (24 FLA) at 120 VAC or 5 HP (28 FLA) at 240 VAC, which Intermatic calls the highest motor load ratings in the industry.
12 ON/OFF Operations a Day
The 24-hour dial allows up to 12 ON and 12 OFF events per day. One ON and one OFF tripper come with the mechanism, and Intermatic lists extra tripper sets (156T1978A) as an accessory.
Manual Override Lever
A manual lever below the dial switches the load on or off by hand without affecting the next scheduled operation.
Teeter-Type Terminals
Teeter-type terminals accept multiple load connections. Intermatic's instructions call for copper conductors rated at least 90 C, solid or stranded.
Fits Most Intermatic Enclosures
This is the mechanism only, with no enclosure. Intermatic states it can be installed in most Intermatic enclosures.
Electrical Safety
Intermatic warns of a risk of fire or electric shock: disconnect power at the circuit breaker or disconnect switch before installing or servicing, and install and wire to national and local electrical codes. Intermatic also states that the heater control switch should not be used in place of a pressure or flow switch in the heater control circuit.
Specifications
| Identification | |
|---|---|
| Manufacturer | Intermatic |
| Model / MPN | T104M201 |
| Series | T100 Series mechanical time switch |
| UPC | 078275124202 |
| SKU | PST-59-155-1210 |
| Enclosure | None, mechanism only |
| Electrical | |
| Input Voltage | 208-277 VAC, 60 Hz |
| Switch Type | DPST, 2 circuits |
| Heater Control Output | 10 A, 250 VAC max, 60 Hz |
| Max Power Consumption | 3 W |
| Load Ratings | |
| Resistive Heater | 40 A, 120-480 VAC |
| Inductive | 40 A, 120-277 VAC |
| Tungsten Incandescent | 40 A, 120-240 VAC |
| Pilot Duty | 1000 VA, 120-277 VAC |
| Motor | 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC |
| Electronic Ballast LED | 16 A, 120/277 VAC |
| Timing | |
| Operation Mode | 24 hour |
| Events Per Day | 12 ON / 12 OFF |
| Trippers Included | 1 ON / 1 OFF |
| Certifications & Warranty | |
| Certifications | cULus, cCSAus |
| Operating Temperature | -40 F to 130 F |
| Color | Gray |
| Country of Origin | Mexico |
| Warranty | 1-year limited (Intermatic) |
Frequently Asked Questions
Does the T104M201 come with an enclosure?
No. Intermatic lists it as a mechanism only, enclosure type N/A, and states it can be installed in most Intermatic enclosures.
How does the pool heater protection work?
Per Intermatic's fireman switch instructions, the heater control contacts stay closed at all times except during the 20 minutes before the pump is scheduled to turn off, which lets the water circulate for 20 minutes without heat. Intermatic says this control should not replace a pressure or flow switch in the heater circuit.
What voltage does it run on?
The T104M201 takes 208-277 VAC, 60 Hz. Intermatic lists a replacement clock motor, WG433-20D (208/277V, 60 Hz), as an accessory.
How do I set the time of day?
Intermatic's instructions say to pull the clock dial outward, turn it to line up the current time with the pointer, and not to move the pointer or the clock hands. Rotate the dial clockwise only, and reset the dial to the correct time after a power failure.
Can I add more ON/OFF times?
Yes, up to 12 ON and 12 OFF operations per day. One ON and one OFF tripper are included, and Intermatic sells extra trippers, 156T1978A (1 ON and 2 OFF).
Order the T104M201 From PST
Backed by PST Pool Supplies' service team.
- Free Shipping
- 30-Day Returns
- 1-Year Intermatic Warranty
- Authorized Intermatic Dealer
Additional Info
| Category | Parts Pool Parts Automation Parts |
| SKU | PST-59-155-1210 |
| MPN | T104M201 |
| Replaces | 3680-61, 56730, 78275124202 |
| Manufacturer | Intermatic |
| Weight | 1.44 lb |