Product Information
Description
- Genuine Pentair Part
- Board #10688
- Free Shipping
Pentair Compool LX-80 Control Center Circuit Board (PCLX80)
Replacement circuit board for the Compool LX-80.
Pentair PCLX80 is the circuit board for the Compool LX-80 commercial pool and spa control, listed by Pentair as board #10688. It carries the low-voltage terminals for the spa jets switch, emergency shut-off switch and gas heater fireman's switch leads, plus the relay sockets for the filter, jets and chlorine pump circuits. PST SKU PST-59-110-2468.
Why PST Customers Pick This
Built for the LX-80
Pentair lists PCLX80 as the circuit board for the LX80, board #10688. The LX820 has its own board, PCLX820.
Plug-Off Terminal Strip
For the serviceperson's convenience, Pentair notes that the 10-position low-voltage screw terminal unplugs from the circuit board without disconnecting the wires.
Switch and Heater Inputs
The board's low-voltage terminals take the RCS-1 spa jets switch (REM 1, with REM 2 for a second switch), the emergency shut-off switch (SHUT OFF) and the pool and spa gas heater leads (POOL GHTR, SPA GHTR).
Relay Sockets on Board
The circuit board carries the JETS 1 and JETS 2 relay sockets, plus POOL ORP and SPA FLTR sockets for chlorine pump relays. Circuits R4 to R7 need added RLY-LX relay kits.
Heater Cool-Down Run
With the fireman's switch leads connected, the LX-80 keeps the filter pump running for ten more minutes after the timer shuts off, to cool down the heater.
Electrical Notice
Pentair requires all LX-80 wiring to be performed by a qualified electrician, following local codes. Never run low-voltage and high-voltage wires in the same conduit, and if no emergency shut-off switch is installed, a jumper must be connected across the SHUT OFF terminals on the circuit board.
Specifications
| Identification | |
|---|---|
| Manufacturer | Pentair (Compool) |
| Pentair Part Number | PCLX80 |
| Pentair Description | Circuit board for LX80, #10688 |
| SKU | PST-59-110-2468 |
| Condition | New |
| Fitment | |
| Control | Compool LX-80 commercial pool and spa control center |
| Not For | LX820 (uses PCLX820, #10853) |
| Connections | |
| Low-Voltage Terminals | REM 1, REM 2, SHUT OFF, POOL GHTR, SPA GHTR |
| Low-Voltage Terminal Block | 10-position, unplugs without disconnecting wires |
| Low-Voltage Cable | Separate 2-conductor 22 AWG cable per device |
| Relay Sockets | JETS 1 (two), JETS 2, POOL ORP, SPA FLTR |
| Optional Circuits | R4 to R7, with RLY-LX relay kits |
| LX-80 System Power | |
| Supply Voltage | 115 VAC or 230 VAC |
| System Draw | Less than 1 amp |
Frequently Asked Questions
Will this board fit an LX820?
No. Pentair lists a separate board, PCLX820 (#10853), for the LX820. PCLX80 is the board for the LX80, #10688.
Do I have to unscrew every low-voltage wire to swap the board?
Pentair notes that the 10-position screw terminal can be unplugged from the circuit board without disconnecting the wires.
What if the system has no emergency shut-off switch?
Pentair says a jumper wire must then be connected between the SHUT OFF screw terminals on the circuit board.
Who should install it?
Pentair says all LX-80 wiring must be performed by a qualified electrician, observing basic safety precautions and local codes.
Order the PCLX80 From PST
Backed by PST Pool Supplies' service team.
- Free Shipping
- Genuine Pentair Part
- Authorized Pentair Dealer
Additional Info
| Category | Parts Pool Parts Automation Parts |
| SKU | PST-59-110-2468 |
| MPN | PCLX80 |
| Manufacturer | Pentair |
| Weight | 0.5 lb |