H2Flow FlowVis FV-C-S Flow Meter with Safety Flapper for 2 in Pipe
FlowVis flow reading, no check valve function.
The H2Flow FlowVis FV-C-S (PST-26-042-1010) is the FlowVis flow meter with a safety flapper, made for 2 in Schedule 40 pipe and reading 30 to 110 GPM on its GPM scale. Unlike the FV-2, H2Flow gives the FV-C-S no check valve function. H2Flow's manual points installers whose VGBA backup anti-entrapment system does not allow check valves to this model.
Why PST Customers Pick This
No Check Valve, by Design
H2Flow lists the FV-C-S with no check valve function, and its parts table gives it a non check valve flapper, where the FV-2 carries a check valve flapper and flapper seal. This is the model H2Flow's manual names for VGBA installs whose backup system does not allow check valves.
Reads 30 to 110 GPM
The FV-C-S carries a GPM scale covering 30 to 110 GPM on 2 in Schedule 40 pipe. For a liters per minute scale, H2Flow makes the FV-C-S-L, rated 110 to 400 LPM.
Zero Straight Pipe
H2Flow lists 0 in of straight pipe before and after the FV-C-S. Its NSF 50 Level 1 rating was certified with zero straight pipe, installed horizontal, vertical up or vertical down.
No Calibration Needed
H2Flow factory calibrates FlowVis and lists no calibration requirement for the FV-C-S. As flow rises, the flapper swings open and its angle sets the reading on the calibrated scale in the clear lid.
Digital Upgrade Ready
H2Flow lists the FV-C-S as compatible with its FlowVis Digital add-ons: the FV-D with a digital display and 4-20mA output, the FV-D-SC signal converter with a 4-20mA output, and the FV-D-Sensor.
Made in the USA
H2Flow lists the FV-C-S as manufactured in the USA, with 95% of FlowVis materials sourced in North America. Every FlowVis model is NSF 50 rated for indoor and outdoor use.
VGBA Systems and Lid Installation
Under the Virginia Graeme Baker Act, public pools and spas with a single main drain, or drains 3 ft or less apart center to center, need a backup anti-entrapment system such as an SVRS or automatic pump shut-off. H2Flow notes that several of these systems do not allow check valves, and the installer is responsible for meeting the requirements of the backup system in use. When you refit the lid, tighten the eight screws by hand in a diagonal pattern to 25 in-lb; H2Flow warns that a power tool will crack the polycarbonate lid and void the warranty.
Specifications
| Identification | |
|---|---|
| Manufacturer | H2Flow Controls |
| Product Line | FlowVis |
| Model / MPN | FV-C-S |
| SKU | PST-26-042-1010 |
| Plumbing | |
| Pipe Size | 2 in |
| Pipe Schedule | Schedule 40 |
| Fitting Type | Valve body, 2 in slip |
| Overall Length | 6.5 in |
| Overall Height | 5.875 in |
| Straight Pipe Required | 0 in before, 0 in after |
| Orientation | Horizontal, vertical up or vertical down |
| Performance | |
| Flow Range | 30 to 110 GPM |
| Scale | GPM (LPM version: FV-C-S-L) |
| Check Valve Function | None |
| Average Accuracy | 98.0% |
| Working Pressure | 50 psi |
| Calibration | Not required |
| Operating Ambient Temperature | 32°F to 140°F (0°C to 60°C) |
| Certification | NSF 50, Level 1 |
| Construction | |
| Lid | Clear polycarbonate |
| Flapper | Non check valve flapper, ABS |
| Lid Screws | 8, 316 stainless steel, 25 in-lb final torque |
| Warranty and Origin | |
| Warranty | 36 months from date of manufacture, H2Flow limited warranty |
| Made In | USA |
Frequently Asked Questions
Is the FV-C-S a check valve?
No. H2Flow lists no check valve function for the FV-C-S, and its parts table gives it a non check valve flapper. If you want a 2 in FlowVis that doubles as a check valve, H2Flow's model for that is the FV-2.
Why would I choose it over the FV-2?
H2Flow's manual notes that several VGBA backup anti-entrapment systems, a group that includes SVRS and automatic pump shut-off systems, do not allow check valves, and refers those installs to the FV-C-S. Confirm what your backup system requires before you choose.
Does it need a straight run of pipe?
No. H2Flow lists 0 in of straight pipe before and after the FV-C-S, and certified it to NSF 50 Level 1 with zero straight pipe in horizontal, vertical up or vertical down installs.
What if I install it facing the wrong way?
Match the arrow on the lid to your system's flow direction. If the body goes in backwards, H2Flow says to remove the eight lid screws and rotate the whole lid assembly 180 degrees, then tighten the screws by hand to 25 in-lb.
What does the warranty cover?
H2Flow's certificate covers FlowVis components found defective in material or workmanship within 36 months from the date of manufacture, repaired or replaced by H2Flow. It excludes tampering, misuse, neglect, improper storage and disassembly by anyone other than H2Flow's authorized representatives, and H2Flow does not cover damage from a failed erosion style chlorine feeder.
Order the FlowVis FV-C-S From PST
Backed by PST Pool Supplies' service team.
- Free Shipping
- 30-Day Returns
- 36-Month H2Flow Warranty
- Authorized H2Flow Dealer
Additional Info
| Category | Pool Products Pool Accessories Pool Flow Meters |
| SKU | PST-26-042-1010 |
| MPN | FV-C-S |
| Replaces | 68255 |
| Manufacturer | H2Flow |
| Weight | 1.74 lb |